Abstract

The performance of a parabolic trough photovoltaic/thermal collector with a geometric concentration ratio of 37× is described. Measured results under typical operating conditions show thermal efficiency around 58% and electrical efficiency around 11%, therefore a combined efficiency of 69%. The impact of non-uniform illumination on the solar cells is investigated using purpose built equipment that moves a calibrated solar cell along the line of the receiver and measures short circuit current. The measured illumination flux profile along the length shows significant variation, despite the mirror shape error being less than 1 mm for most of the mirror area. The impact of the illumination non-uniformities due to the shape error, receiver support post shading and gaps between the mirrors is shown to have a significant effect on the overall electrical performance. The flux profile transverse to the receiver length is also investigated. Peak flux intensities are shown to be around 100 suns. The impact on efficiency due to open circuit voltage reduction is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.