Abstract

A 1700 m2 solar pond was constructed in the desert of Kuwait where severe weather conditions prevail in all seasons. The paper describes in detail a diffuser design for the gradient establishment, gradient stability, and thermal performance of the pond. The main problem encountered in operating the pond was mixing between the upper zone and the gradient zone, even when the wind speed was as low as 5 m/s. No mixing between the gradient and the lower connective zone was observed. The wind effect was severe in causing mixing even when the upper convective zone increased to 0.90 m.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.