Abstract
An optical fiber strain-sensing technique, on the basis of Brillouin optical time domain reflectometry (BOTDR), was used to monitor the performance of a secant pile wall subjected to multiple props during construction of an adjacent basement in London. Details of the installation of sensors and data processing are described. Distributed strain profiles were obtained by deriving strain measurements from optical fibers installed on opposite sides of the pile to allow monitoring of both axial and lateral movements along the pile. Methods for analyzing the thermal strain and temperature compensation are also presented. Measurements obtained from the BOTDR were found to be in good agreement with inclinometer data from the adjacent piles. The relative merits of the two different techniques are discussed.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Geotechnical and Geoenvironmental Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.