Abstract
The aim of this paper is to study and investigate the performance of power factor correction (PFC) circuit implemented with the semi bridge-less configuration. The transistor-diode module APT50N60JCCU2 has been used in the proposed circuit and the UCC28070 controller has been used as a controlling device for the power factor correction (PFC) circuit. Testing has been performed in two steps. In the first step, the test was conducted<br /> on (230 Vac), while in the second step, the test was conducted on (115 Vac) as alternating input voltages. The testing results of both voltages were compared and analyzed in terms of efficiency, power factor, total harmonic distortion (THD) in order to determine the efficiency of the power factor correction circuit. The results obtained indicate that this circuit has efficiency up to 97% and a power factor close to 0.91 with the input voltage of 230 V.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Power Electronics and Drive Systems (IJPEDS)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.