Abstract

This paper demonstrates an approach to minimize the harmonics contained in the output of a single phase full bridge inverter modulated by phase displacement control so as to improve the Total Harmonic Distortion (THD). With a view to reducing harmonics an LC low pass filter is used which blocks the harmonics and undeniably passes almost sinusoidal output at the output terminal and it is certainly true that THD has been improved to a great extent. An illustration of Fourier Transform has been provided in this paper in order to perceive both the fundamental and harmonics component precisely. It has been found from simulation that the Total Harmonic Distortion (THD) before and after the application of LC low pass filter is 33.34% and 0.003% respectively. That is why this LC low pass filter is quite effective to reduce THD of a 1-phase full bridge inverter. 

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.