Abstract
The performance of a solar air heater featured with double-pass as well as fins and baffles design was investigated for the effect of recycling operation via both experimental and theoretical approaches. The experimental results deviate by 1.5–23% from the theoretical predictions. The performance of solar air heaters with different designs are compared, including the single-pass, double-pass with recycle, fined double-pass with recycle, and fined plus baffled double-pass with recycle. The double-pass device introduced in this study was proposed for aiming to strengthen the convective heat transfer coefficient and enlarge the heat transfer area. Based on both theoretical and experimental results, the collector efficiency of the fined plus baffled double-pass with recycle design is much higher than the other designs under different reflux ratios and mass flow rates. The optimal reflux ratio for the fined plus baffled double-pass design is about 0.5 while considering both the collector efficiency and the pumping power requirement. An economic consideration in terms of the heat transfer efficiency and power consumption increment for double-pass operation is delineated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.