Abstract
The vaneless diffuser (VLD) is usually adopted in the traditional design of the multi-stage centrifugal compressor because of the stage's match problem. The drawback of the stage with vaneless diffusers is low efficiency. In order to increase the efficiency and at the same time, induce no significant decline in the operating range of the stage, three different types of vaned diffusers are designed and numerically investigated: the traditional vaned diffuser (TVD), the low-solidity cascade diffuser (LSD) and the partial-height vane diffuser (PVD). These three types of vaned diffusers have different influences on the performance of the centrifugal compressor. In the present investigation, the first part investigates the performance of a centrifugal compressor stage with three different vaned diffusers. The second part studies the influences of the height and the position of partial height vanes on the stage performance, and discusses the matching problem between the PVD and the downstream return channel. The stage investigated in this paper includes the impeller, the diffuser, the bend and the return channel. In the process of numerical investigation, the flow is assumed to be steady, and this process includes calculation and simulation. The calculation of 3-D turbulent flow in the stage uses the commercial CFD code NUMECA together with the Spalart-Allmaras turbulence model. The simulation of the computational region includes the impeller passages, the diffuser passages and return channel passages. The structure and surrounding region are assumed to have a perfect cyclic symmetry, so the single channel model and periodic boundary condition are applied at the middle of the passage, that is to reduce the calculation region to only one region. The investigation showed that the low-solidity cascade diffuser would be a better choice as a middle course for the first stage of the multistage centrifugal compressor. Besides, the influences of the height and the position of partial height vanes on the stage performance are intensively investigated and concluded at the design point, the isentropic efficiency and the static pressure ratio of the stage are improved with the increasing of the partial vane's height, and that installing the half-height vanes on the shroud side the stage would obtain a more uniform diffuser outflow and a better aerodynamic performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.