This paper presents a predictive current control algorithm for a synchronous buck converter using an extended Kalman filter (EKF) algorithm. The predictive approach avoids the need of current-sensing circuitry and provides insensitivity to Gaussian noise sources at the output of the buck converter, which is the same as the control loop input. The method requires a model for the buck converter, the EKF design, and current loop tuning. All these prerequisites are described in this work along with the implementation of the algorithm in a state of the art microcontroller. Simulation and experimental results show that while maintaining a good step response, the proposed method provides better results than standard methods when Gaussian noise is present at the output voltage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.