Abstract
Introduction. Rationale of the topic of this article is the need to improve the effectiveness of fire detection. One of the modern solutions to this problem is the use of video technology. The article is aimed at developing a method to assess the effectiveness of video surveillance in the fire protection system on the basis of the formed mathematical model.Methods of research. The fire risks theory is used for formation of mathematical model. The potential fire detection risk is introduced as a quantitative measure of the possibility of undetected fire occurrence at the protected facility, development and implementation of its consequences for people and material valuables. It is calculated as the product of the maximum probability of fire by the probability of its non-detection by the technical means and alarm systems used. The efficiency of video surveillance use in the fire protection system is determined on the basis of compliance of the complex risk index of fire non-detection with the permissible value.Research results. The possibilities of increasing the efficiency of fire detection through the use of video technology are considered. Reducing the fire detection risk can be achieved by using video channel fire detectors that reduce the time it takes to reliably detect a fire. The probability of reliable detection is an important parameter of the detector during its operation in the fire alarm system and characterizes the degree of performance of its main function. The main ways to improve the efficiency of fire detection are the improvement of fire detectors with video channel, the joint use of fire video detectors and other detection devices, such as automatic multi-criteria detectors, thermal imaging сamera, as well as the use of photo and video in centralized surveillance systems.Conclusions. The offered method of estimation of efficiency of application of video surveillance in fire protection systems can be used for a substantiation of parameters of technical means (systems) of the fire alarm system and passive fire-fighting measures established on the facility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Pozharovzryvobezopasnost/Fire and Explosion Safety
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.