Abstract
Magnetic heat pumps and cooling systems typically use a magnetocaloric material in an active magnetic regenerator (AMR) cycle for application near room temperature. One method of improving AMR performance is to layer regenerators with spatially varying Curie (or transition) temperatures. To study the impact of layering on AMR performance, four regenerator compositions comprised of two-layers are experimentally tested with interface temperature measurements. Each regenerator uses Gd as the layer with the highest Curie temperature; the second layer uses Gd and three compositions of Gd1−xYx. The four regenerators are the same size and are tested using three different rejection temperatures and displaced volumes. Numerical simulations are in good agreement with the experimental results. The two-layer regenerators present the largest performance improvements for the no-load conditions and, in general, develop the peak exergetic cooling power for almost all operating conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.