Abstract

AbstractHigh‐shear impellers (HSIs) are mixers used in industrial stirred tanks to incorporate powders into liquids and break down particle agglomerates. A detailed numerical study of two commercial ring‐style HSIs of laboratory scale was carried out and their performance was compared with the Rushton turbine (RT). It was found that power and pumping numbers or their ratio cannot be simply connected for properly selecting an impeller in applications where highly localized viscous dissipation is desirable. The ratio of the average viscous dissipation in the impeller swept volume to the mean in the entire volume at two constant values of power input turned out to be lower for HSIs compared to that evaluated for RT. However, at higher power input, the dimensionless average viscous dissipation in the blade swept volume was found to be similar for the HSI of two rings and the RT, corroborating the high local viscous dissipation of this HSI when operated at higher speeds.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.