Abstract

BackgroundThe availability of effective direct-acting antiviral therapy for hepatitis C virus (HCV) has led to a need for simplified diagnostic pathways. Barriers to treatment uptake, specifically in people who inject drugs and in remote and resource limited settings, may be overcome by utilizing novel collection methods, such as dried blood spots (DBS). However, there are currently no registered assays for HCV RNA testing from DBS samples. ObjectivesTo evaluate the sensitivity and specificity of the Aptima HCV Dx Quant assay for HCV RNA detection in DBS samples Study design107 paired venepuncture and DBS samples from HCV antibody positive individuals were analyzed for HCV RNA on the Aptima HCV Dx Quant and Roche CAP/CTM (gold standard) HCV assays. Results78% (n=83) had detectable HCV RNA in plasma. Sensitivity of the Aptima assay for HCV RNA detection in DBS was 96.4% (95% CI 89.8–99.3%) and specificity was 95.8% (95% CI 78.8–99.9%). Sensitivity for HCV RNA detection in DBS using a quantitative threshold of ≥15 IU/mL in plasma was 95.1% (95% CI 88%–98.7%) and specificity was 96.0% (95% CI 79.7%–99.9%). The sensitivity of HCV RNA detection in DBS using a quantitative threshold of ≥1000 IU/mL (based on a clinically relevant threshold) was 100% (95% CI 95.3–100%) and specificity was 100% (95% CI 88.4–100%). ConclusionsOur data indicates that the Aptima HCV Dx Quant can detect active HCV infection from a DBS sample with good sensitivity and specificity, particularly when using a threshold of ≥1000 IU/mL.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call