Abstract

A 69 MVA pump-generator with corona resistant filled polyimide film applied as stator coil strand insulation has been returned to service. Design modifications were implemented to take advantage of the new insulation system; testing results of these unique 13 kV stator coils are discussed. Operation data from the rewound machine is presented. This is a companion paper to Application of Corona Resistant Polyimide Film to Pump Generator Stator Coils presented at ISEI 2004

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.