Abstract

Tropical region such as Darwin has similar weather patterns throughout the year, thus creating higher energy demands in residential buildings. Typically, buildings consume about 40 per cent of the total energy consumption for indoor heating and cooling. Therefore, building envelopes are linked with design strategies such as the use of thermal energy storage and phase change materials (PCM) to minimize this energy consumption by storing a large amount of thermal energy. Primarily, PCMs are targeted by researchers for use in different components of buildings for thermal efficiency; thus, this study aimed to provide a suitable PCM to optimize indoor thermal comfort and minimize the cooling loads of residential buildings in tropical climates through simulation of a tropical climate building and provide optimum thickness for the selected material. Microencapsulated PCM mixed with gypsum in wallboards were used to reduce the cooling load of a building located in Darwin. The cooling load of the building was calculated using Revit software. A comparison of the cooling load of the building was carried out using PCM-incorporated wallboards of thicknesses of 0 cm, 1 cm and 2 cm in Energy Plus software. The total cooling load decreased by 1.1% when the 1-centimetre-thickness was applied to the wall, whereas a 1.5% reduction was obtained when a 2-centimetre-thick PCM layer was applied. Furthermore, the reduced cooling loads due to impregnation of the PCM-based gypsum wallboard gave reduced energy consumption. Ultimately, the 2-centimetre-thickness PCM-based gypsum wallboard gave a maximum reduction in cooling load with a 7.6% reduction in total site energy and 4.76% energy saving in USD/m2/year.

Highlights

  • This study was aimed at investigating phase change materials to optimize indoor thermal comfort and minimize the cooling loads of residential buildings in tropical climates

  • This study investigated the incorporation of phase change materials (PCM) based gypsum wallboard at the internal side of composite walls of a building located in Darwin, Australia

  • The effect of PCM position and thickness was assessed in two scenarios

Read more

Summary

Introduction

For the last three decades, the energy efficiency of buildings has been getting much attention due to the substantial energy demands of maintaining indoor thermal comfort in modern buildings [1,2]. It is critical to construct energy-efficient buildings as the increased demand for fossil fuel creates environmental problems like climate change and an increase in the cost of fossil materials [3]. Buildings were constructed with wider walls that could store a large amount of sensible heat and provide natural conditioning by controlling the temperature variations [4]. In modern buildings, Sustainability 2022, 14, 3171.

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have