Abstract

In present communication, an experimental study has been carried out to evaluate the performance of series connected photovoltaic thermal (PVT) water collector in terms of overall thermal energy gain and overall exergy gain. Earlier developed theoretical model has been validated by performing the experiment in a clear sky day, hazy day and partially cloudy day for New Delhi climatic condition. It was found that theoretical results were in good agreement with experimental results. The annual energy gain, exergy gains, CO2 mitigation, energy matrices and carbon credit of the system have also been discussed. The energy pay-back time was found to be 1.50 and 14.19years on overall thermal energy and exergy basis respectively. Carbon credits earned in a year were Rs. 6321.70 for overall thermal energy gain and Rs. 667.30 for overall exergy gain. For 30years of life time, cost of one unit of electricity was estimated to be Rs. 1.53 on overall thermal energy basis however it was Rs. 14.45 on overall exergy basis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.