Abstract

This paper presents a performance comparison between two dimming methods for an electronic ballast that feeds a T5 HE 28 W fluorescent lamps. An IR21592 dedicated integrated circuit is employed in the half-bridge inverter stage with a LCC resonant filter. A PFC stage is implemented with a Single-Ended Primary Inductance Converter with constant output voltage or variable output voltage according to the dimming method. A standard circuit IR21592 is employed to dim the lamp based on a standard method of inverter frequency variation with a constant PFC output voltage. A modified operation mode of IR21592 is employed also to dim the fluorescent lamp through a PFC stage output voltage and inverter frequency variation dimming method. For both methods experimental results are presented in order to make a comparison and to evaluate the general performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.