Abstract
AbstractA methane telemetry system for 1653 nm DFB laser based on TDLAS‐WMS technology is developed in this article. The focus tunable lens is used as the collimating system of the telemetry device to solve the problem that the telemetry device cannot be dynamically adjusted under different detection environments. Experimental results show that the root mean square error was 7.6205 and the theoretical limit of detection (LoD) was 1.473 parts per million (ppm) while the optimal integration time reaches 30 s. The near‐infrared CH4 telemetry system is suitable for different detection environments of natural gas leakage and has good detection performance and stable and reliable operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.