Abstract

As medium voltage dc-based (MVDC) technology is widely considered in the shipboard integrated power system (IPS), the short fault protection of shipboard IPS is urgent. This paper suggests resistive type superconducting fault current limiter (R-SFCL), flux-coupling type SFCL (FC-SFCL), and a hybrid type SFCL (H-SFCL) alleviate fault current and improve the transient behaviors of shipboard MVDC IPS. All of these SFCLs are installed at the DC line. When pole to pole short fault occurs, resistive and inductive components play roles in current limiting. To evaluate these SFCLs and choose one for the system, theoretical analysis, simulation verification and experiments are done. According to the current limiting and economic cost index, H-SFCL is preferable in these SFCLs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call