Abstract

This paper presents performance comparison of High-voltage High-frequency Ozone Generator using PWM and Phase-Shifted PWM full-bridge inverter as a power supply. The circuits operations of the inverter are fully described. In order to ensure that zero voltage switching (ZVS) mode always operated over a certain range of a frequency variation, a series-compensated resonant inductor is included. The performance comparison are ozone quantity and output voltage that supplied by the PWM and Phase-Shifted PWM full-bridge inverter. The ozone generator fed by Phase-Shifted PWM full-bridge inverter, is capability of varying ozone gas production quantity by varying the frequency and phase shift angle of the converter whilst the applied voltage to the electrode is kept constant. However, the ozone generator fed by PWM full-bridge inverter, is capability of varying ozone gas production quantity by varying the frequency of the converter whilst the applied voltage to the electrode is decreased. As a consequence, the absolute ozone quantity affected by the frequency is possibly achieved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.