Abstract

This article presents a control performance comparison of electrorheological (ER) fluid-based valves between cylindrical and plate configurations. After identifying Bingham characteristics of chemical starch-based ER fluid, an analytical model of each valve is established. In order to reasonably compare valve performance, design constraint is imposed by the choosing the same electrode gap and length, and each ER valve is manufactured. Valve performances such as pressure drop and response time are then evaluated and compared through analytical model and experiment. In addition, a time-varying pressure tracking controllability of each ER valve is experimentally realized.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.