Abstract

In this paper, the performances variation of a refrigerating system of the small capacity inverter-driven air conditioner at the different operating frequencies using the electronic expansion valve and capillary tube individually are analyzed. The mathematical models and the steady model of the refrigerating system which have been verified by the experiments. The analysis shows that more advantages could be obtained for the air conditioner with the electronic expansion valve at the frequencies of 20Hz-120Hz, however, the air conditioner applying the capillary tube has the acceptable performance in the major frequency range of 40Hz-80Hz at the most time so that it is feasible for the small capacity inverter-driven air conditioner to employ the capillary tube as the throttling device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.