Abstract

Studies indicate that power required for ice bank bulk milk tanks averaged about 1.0 kw-hr per cwt. of milk while direct expansion tanks averaged 0.65. Both compare favorably with 2.0 for mechanical can coolers cooling to the same temperatures. Lower purchase prices for ice bank coolers may offset most of the power increase over the direct expansion type. Some ice bank tanks were underpowered and same had insufficient ice bank capacity to complete milk cooling to 40° F. within two hours after milking. One direct expansion tank using air cooling only did not meet this cooling requirement when operating in the 84° to 88° F. temperature range.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.