Abstract

Performance characteristics of a packed bed ozone contact was investigated. A yellow dye was employed as the tracer to test the dispersion characteristics of the ozone contactor in the single‐phase (liquid) and two‐phase (countercurrent liquid/air) flow systems. The one‐parameter (tanks‐in‐series) and two‐parameter (combined plug‐flow/tanks‐in‐series) models were employed to fit the observed residence time distribution (RTD) functions. It was found that for the one‐parameter model, at least twenty well‐mixed tanks are required to reasonably fit the observed RTD functions while for the two‐parameter model, only a fewer well‐mixed tanks plus a plug flow reactor are needed to yield the same fit. The dispersion characteristics of flow in the ozone contactor could also be represented by the dispersion model with appropriate dispersion numbers. The experimental residence time distribution functions were employed in conjunction with the reaction kinetics to determine the discolorization of dyestuff by ozonation in the packed bed reactor. The experimental observations appeared to reasonably confirm the theoretical predictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.