Abstract

In this study, the performance of a triple redundant nine-phase permanent magnet-assisted synchronous reluctance motor with delta-connected windings is comprehensively assessed and compared with that of wye-connected winding under healthy and fault conditions, including open circuit, inter-turn short-circuit and terminal short circuit. The steady-state torque behaviour, loss, efficiency and temperature distribution of the two winding configurations are analysed and compared. It is shown that the delta-connected winding has higher output torque under one phase open-circuit fault and lower inter-turn short-circuit current with three-phase terminal short circuit.