This paper evaluates the performance of a seven-story reinforced concrete frame building that was severely damaged during the 1994 Northridge, California, earthquake. The building was designed and constructed in the 1960s and contains details that are typical of that construction era in the western United States. The building sustained severe damage that included column shear failures. The building was analyzed independently by three research teams using analysis methodólogies that were similar in concept but different in details. An objective of each analysis was to correlate observed and calculated performance. The different analyses were successful to varying degrees. The results provide a test case of the effectiveness of various seismic performance assessment methodologies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.