Abstract
The study investigated the comparative thermal performance and energy saving abilities of environment-malignant R22 and eco-friendly R290 refrigerants in a domestic air-conditioning system. It focused on studying the effect that the thermodynamic (fluid) system has on the performance indices of the refrigerants. The fluid system was reconfigured to include bio-based (Citrullus Lanatus peels (watermelon peels)) nanoparticles, dispersed in Capella D oil at different concentrations of (0.05, 0.1, and 0.2) vol%. Various performance analyses such as cooling capacity (CC), energy consumption, coefficient of performance (COP), thermal conductivity and viscosity were considered. The results showed that R22 performed better than R290 in terms of COP and CC while R290 was preferred considering energy consumption and other thermodynamic performance variables. However, when the thermodynamic system was reconfigured to contain the bio-based nanoparticles, the outcome showed that the nanoparticles subsequently improved the overall thermodynamic performance and energy consumption of R290.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.