Abstract

Knowledge deficiency in design concepts promotes the performance investigation of post-installed large diameter anchor systems. The investigation involves testing of 48 specimens, including four combined-anchor types (grout-plain, grout-grooved, epoxy-plain, and epoxy-grooved). Anchor bars with diameters 36mm, 48mm, 90mm, 150mm were chosen, and the selected embedment depths were 8, 10, 12 times the bar diameters. Results indicated that tensile capacity is related to the bar diameter, anchoring agent, bar surface type, and embedment depth. Based on the results and existing design models, a modified design equation is proposed. A comparison of test results with the results of modified equation shows that the modification provides a better estimation for the post-installed large diameter anchor systems. The modified equation can be applied to the design of anchoring reinforcement for engineering.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.