Abstract

The performance and plume characteristics of a 2-kW Hall thruster with segmented anodes for thermal control of the main anode are characterized. Diagnostics performed included thrust, specific impulse, and efficiency, as well as the ion current density in the plume. The apparatus included an inverted-pendulum thrust stand for performance measurements and a shielded Faraday probe for ion current density characterization. Data were taken at several operating points and at several ratios of current to the main anode vs the shim electrodes. The data show a general increase in centerline current density, thrust, specific impulse, and efficiency as discharge current is moved to the shims. Thermal measurements show up to 50° C control authority in the main anode temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.