Abstract
Experimentally to analyzed the enhance performance of Plate heat exchanger in milk pasteurization process using nanofluid at different concentration of 0.1%,0.15%,0.2% 0.25% and 0.3%. in this work the nanoparticles like Al2O3 and the base fluid like dematerialized water is used to prepare nanofluid by using two steps method. Exchanger is one of the thermal energy transferring devices, which transfer the heat between different fluids. This is widely used in different application because of its compact in size and higher efficiency compared to other type of heat exchanger. The main focus of using nanofluid is that it has improvement in thermal conductivity. Then the hot fluid as milk and cold fluid as nanofluids are used. The heat transfer rate is increased with increasing the concentration of nanofluid. It conducted by varying operating parameters like mass flow rate of hot milk, mass flow rate of nanofluid, inlet and outlet temperatures of hot milk and inlet outlet temperature of nanofluid. The main objective of this work is to find out mass flow rate and overall, all heat transfer coefficient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.