Abstract

Linear compressor is a promising alternative for commercial refrigerator using R290. In this paper, a design program of linear compressor is set up. The leakage mass flow rate is modeled based on small hole leakage principle. The errors of the model are within 10%. The cooling performance of linear compressor with different piston diameter for commercial referigerator using R290 is analyzed. As the linear compressor is set to have the same swept volume, small piston diameter is beneficial to the COP improvement, but has a few decrease of cooling capacity. As the linear compressor is set to have the same cooling capacity by adjusting power frequency, COP of the linear compressor with piston diameter of 28 mm and 30 mm gets a little decrease because the power frequency deviates from the inherent frequency. The optimal piston diameter of 12 CC swept volume for the commercial refrigeration is suggested to be from 30 mm to 32 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.