Abstract
The nongenerative-boost type rectifier, which is called the Vienna rectifier, is advantageous in terms of efficiency and current total harmonic distortion. Therefore, the Vienna rectifier is used in grid-connected applications such as telecommunication systems and wind turbine systems. Owing to the structural characteristics of the Vienna rectifier, various switching methods exist. Among these methods, a carrier-based discontinuous pulse-width modulation (CB-DPWM) method guarantees high efficiency compared to continuous pulse-width modulation methods; moreover, it is simple compared to a DPWM method based on space vectors. In this paper, the performance of the CB-DPWM method, its applicable region depending on the power factor and modulation index ( $M_{a}$ ), and its efficiency are analyzed in detail. Then, based on the analysis, a neutral-point voltage balancing method for the CB-DPWM method is proposed. The effectiveness and performance of the proposed neutral-point voltage balancing method are verified by simulation and experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.