Abstract
Efficiency is a crucial design parameter in any turbine development. This research presents a detailed investigation on the efficiency of a modern transonic high-pressure turbine. The work focuses on the study of the efficiency loss at different stage loading factors (ranging from Δ H/U2 = 1.3 to 2.7) and various flow factors ( Vax/ U = 0.41 to 0.90). In particular, the present research is of utmost importance to understand the effect of the vane trailing edge shocks in the turbine stage efficiency. The experimental work was carried out in a compression tube facility that allows testing of the turbine at temperature ratios, Re and Mach numbers, encountered in real engines. The efficiency is measured by the mechanical method. Experiments were performed with two different vanes (cooled and uncooled) at two stagger angles, four rotational speeds (4570–6500 r/min) and three pressure ratios ( p01/ Ps3 ranging from 2.42 to 5.12). The effect of the change of reaction and rotor incidence is correlated with the performance. Three-dimensional Navier-Stokes calculations aid the interpretation of the results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.