Abstract

Abstract This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a φ7.5 cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes (D u /D i ), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow (TSS over/in ) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow (TSS under/in ) increased. There was no visible difference in the TSS over/in with increasing D u /D i ratio, but the TSS under/in decreased sharply. The particle removal efficiency was mainly affected by the particle size. Keywords : Hydrocyclone, Particle, Separation efficiency, Rainfall runoff