Abstract

In the present study, a thermodynamic analysis of thermal performance is carried out in a regenerative GT power plant. The optimization procedure of design parameters is realized by the response surface methodology (RSM). The thermodynamic simulations were carried out using the EES code for numerous variables such as compression ratio (2≤rp≤12), inlet temperature (273≤T1≤313K), turbine inlet temperature (1200≤T3≤1600K), and regenerator effectiveness (45≤ε≤85%). Analysis of variance (ANOVA) was carried out to identify the process parameters that influence thermal efficiency (ηth) and specific fuel consumption (SFC). Then, a second-order regression model was developed to correlate the process parameters with ηth and SFC. Consequently, numerical and graphical optimizations were performed to achieve multi-objective optimization for the desired criteria. According to the desirability function approach, it can be seen that the optimum objective functions are ηth=50.61% and SFC=0.117 kg/kWh, corresponding to process parameters T1=273.26K, T3=1597.64K, rp=6.95 and ε=84.89%. Lastly, verification simulations were conducted to validate the importance of the generated statistical models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call