Abstract
Recovering compression waste heat using latent thermal energy storage (LTES) is a promising method to enhance the round-trip efficiency of compressed air energy storage (CAES) systems. In this study, a systematic thermodynamic model coupled with a concentric diffusion heat transfer model of the cylindrical packed-bed LTES is established for a CAES system, and the numerical simulation model is validated by experimental data in the reference. Based on the numerical model, the charging–discharging performance of LTES and CAES systems is evaluated under different layouts of phase change materials (PCMs) in LTES, and the optimal layout of PCM is specified as a three-stage layout, since the exergy efficiency of LTES and round-trip efficiency are improved by 8.2% and 6.9% compared with a one-stage layout. Then, the proportion of three PCMs is optimized using response surface methods. The optimization results indicate that the exergy efficiency of LTES and round-trip efficiency of the CAES system are expected to be 80.9% and 73.3% under the PCM proportion of 0.48:0.3:0.22 for three stages, which are 7.0% and 13.1% higher than the original three-stage PCMs with equal proportions.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.