Abstract

Perfluoroctylbromide (PFOB) in emulsion form was tested as a blood pool imaging agent for computed tomography (CT) in five animals (three dogs and two pigs). Computed tomography of the kidneys, liver, spleen, and mediastinum was performed in the control state and at various time intervals after the end of PFOB infusion. The attenuation coefficient of the vascular space increased by 117 Hounsfield units (HU) (range 105-128 HU), the liver by 54 HU (range 43-70 HU), and the spleen by 77 HU (range 69-86 HU) 30 to 50 min after the end of PFOB infusion, 5 ml/kg. The vascular space enhanced by 25 HU for every g of PFOB/100 ml of blood and remained at almost a constant level for hours after the end of infusion. In conclusion, PFOB emulsion, in addition to hepatosplenic enhancement, produces prolonged and substantial opacification of the vascular space, allowing CT imaging of the heart and vascular structures minutes to hours after the end of infusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.