Abstract

In this paper, we use an analytical model to investigate voltage drop across the conductors of a three-phase parallel wire planar transmission line carrying balanced currents. The expressions derived for the voltage drops are identical to those given by the perfect conductor model except for a term arising due to the propagation of fields inside the conductors. The voltage drops thus calculated yield different values for the two end conductors even when they are symmetrically placed with respect to the central conductor. The calculations show that the imaginary part of the correction term is of more significance than the real part. The results obtained show agreement with the measured values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.