Reconstruction of intra-articular impression fractures of the middle phalanx by percutaneous reduction over asmall dorsal cortical window. Stabilization by lattice-like arranged K‑wires. Impression fractures of the base of the middle phalanx with or without dislocation in the proximal interphalangeal joint. Fractures extending to the shaft of the middle phalanx. By acortical window at the dorsum of the middle phalanx (through the tendon free triangle) the impression fracture is reduced from the medullary cavity. Reduction is secured and the articular surface is supported by lattice-like arranged K‑wires. Thermoplastic splint for the finger for 6weeks, subsequently K‑wire removal, active range of motion exercises and hand occupational therapy. In two case series already published, good clinical and radiological results were reported. No complications were detected in either series.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.