Abstract
PurposeTo evaluate the technical and clinical success of percutaneous superior mesenteric vein (SMV) stenting in symptomatic patients using self-expanding nitinol stents. MethodsWe retrospectively analyzed the technical and clinical success of percutaneous SMV stenting of 6 symptomatic patients (3 men, mean age 67 years, range 48–81 years). Stenosis of the SMV was caused by postoperative stricture (n=3), pancreas carcinoma (n=1) and pancreatitis (n=2). As a result of the stenosis, 3 patients had symptomatic ascites, 2 patients showed signs of mesenteric ischemia and 1 patient had recurrent gastrointestinal bleeding. Stenting was performed by a percutaneous transhepatic approach using self-expanding nitinol stents. ResultsStenting of the SMV was technically and clinically successful in all patients. No peri-interventional complications occurred. The stent diameters ranged from 6 to 14mm. During the mean follow-up of 6 months (range, 2–10 months) 1 patient presented early stent occlusion 2 weeks after placement. ConclusionStenting of a symptomatic SMV stenosis using self-expanding nitinol stents is feasible and clinically effective.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.