BackgroundUltrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein.Case presentationDuring pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation.ConclusionThe attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound imaging. Appropriate training and supervised experience in ultrasound guided venous access coupled with quality ultrasound equipment would most likely have significantly diminished the likelihood of this complication. The potential for significant patient morbidity, and possible mortality, was prevented by implantation of an arterial stent-graft.
Highlights
Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation
The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter
The was no analysis of the data to determine if operator experience, or training, had any influence upon success rates and complications
Summary
The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. [4] Common sense dictates that adequate training and experience are pivotal for the provision of safe and effective health care. This 77 year old woman was being prepared for an aortic valve replacement and tandem aorto-coronary bypass graft surgery. The anesthetist used a Site-Rite 3 (Bard Access systems, Salt Lake City, UT, USA) ultrasound unit while attempting to access the right internal jugular vein for venous sheath placement. The image demonstrates the ventral, proximal entry point of the sheath into the subclavian artery (black arrow)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.