Abstract
Background: Percutaneous nephrostomy (PCN) is commonly indicated for upper urinary tract drainage in case of obstruction or fistula. Only a few cases of PCN catheter misplacement into the inferior vena cava (IVC) have been published. Case Presentation: We report a case of a PCN catheter misplaced into the IVC through a fistula between the urinary tract and an ipsilateral renal vein in a patient with horseshoe kidney, after bedside urgent replacement for hemorrhage and hemorrhagic shock. Conclusion: Although a nephrostomy Foley catheter can be used for adequate urinary drainage and hemostatic purposes after percutaneous nephrolithotomy, its placement should be always verified through antegrade pyelography and particular care should be used for horseshoe kidneys. In case of massive hemorrhage, after temporary closure of the PCN catheter, the cause of bleeding should be investigated with urgent angiography or contrast-enhanced CT scan and promptly treated.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.