Abstract
The efficacy and safety of two different percutaneous transfemoral mitral balloon valvuloplasty procedures were evaluated in 45 patients. A double-balloon technique with Mansfield balloons was applied in the first 22 patients (group A), and an Inoue single-balloon technique was used in the subsequent 23 patients (group B). Mean diastolic gradient decreased from 17 ± 7 mm Hg to 8 ± 3 mm Hg ( p < 0.001) in group A and from 13 ± 4 mm Hg to 8 ± 3 mm Hg ( p < 0.001) in group B. The mitral orifice area increased from 1.1 ± 0.3 cm 2 to 2.2 ± 0.8 cm 2 ( p < 0.001) in group A and from 1.2 ± 0.4 cm 2 to 1.7 ± 0.7 cm 2 ( p < 0.001) in group B. The length of the total procedure and the total fluoroscopy time were considerably shorter in group B (86 ± 24 minutes and 18 ± 7 minutes) compared with group A (128 ± 38 minutes and 35 ± 14 minutes; p < 0.001). Mitral regurgitation (grade 3/4) was observed after the procedure in two patients in group A but in nine patients in group B. Cardiac tamponade occurred in two patients in group A, but no major complications were seen in group B. The Inoue single-balloon technique seemed to be safe, easier to perform, and equally effective.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.