Abstract
Purpose: To evaluate the effectiveness of percutaneous mechanical declotting in thrombosed dialysis graft. Materials and Methods: Thirty-two patients with thrombosed dialysis graft in 260 cases involving insufficient hemodialytic access underwent mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Results: Technical success was achieved in 24 of 32 cases, with a procedure time of 30 -240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pul-monary embolism. The six-month patency rate was 67.8%. Conclusion: Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpen-sive, safe and fast, and is well tolerated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.