Abstract
The use of the Impella 2.5 liter (L) device for hemodynamic support has been well described. The typical access site for the Impella 2.5 L device is the femoral artery. The use of the axillary and subclavian artery has been described via surgical cut down for the Impella 5 L device when femoral artery access is not possible. In patients with severe aortoiliac disease and difficult anatomy the femoral artery access for the Impella 2.5 L device is not feasible. We describe the successful percutaneous use of the Impella 2.5 L device for hemodynamic support via the left axillary artery in 2 patients undergoing high-risk PCI with concomitant severe aortoiliac disease.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.