Abstract

Objective: To present initial experience of 12 cases of percutaneous plating of the comminuted fractures of the humerus using minimal access surgery and standard low-contact dynamic compression plate. Patients and Methods: Twelve patients (11 males and 1 female) with an average age of 29.8 years (range 17–46 years) with comminuted diaphyseal fractures of the humerus were treated by minimal access surgery using standard AO/ASIF implants. Fracture was reduced indirectly either by manipulation or by a femoral distractor. Image intensifier was used to monitor the reduction and fixation. The plate was fixed on the anterior surface of the humerus using proximal and distal minimal incision on the anterior aspect of the upper arm. Results: All fractures were united, and all patients had a good range of motion in the adjacent joints. In 1 patient, there was a transient neurological deficit. Conclusion: Percutaneous fixation of comminuted fractures of the humeral shaft is an alternative to standard open surgery, reducing the surgical impact and giving an excellent functional result.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.