Abstract
A 72-year-old male with effort angina pectoris and old myocardial infarction underwent percutaneous coronary intervention (PCI). A 4 Fr sheath was inserted in the radial artery. After diagnostic angiography, a guidewire was inserted from the diagnostic catheter. The diagnostic catheter is removed, and the distal tip of the guidewire remains in the coronary artery. Intravascular ultrasound (IVUS) could be performed via the 4 Fr sheath without guiding catheters. IVUS-guide PCI was successfully performed with 4 Fr sheath, although IVUS requires at least a 5 Fr or larger system. This technique is called "The Emperor's New Clothes Technique" because PCI is performed as if an invisible guiding catheter was being used.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.