Abstract

Small caliber needle aspiration of lung lesions has been successfully and safely used for diagnostic purposes. We report our initial experience using computed tomography-guided fine needle percutaneous implantation for direct intralesional high-dose rate brachytherapy for malignant pulmonary lesions. Twenty patients with primary lung cancer or metastatic cancer which involved the lung or chest wall were treated with a high-dose rate remote afterloader. Eighteen of the 20 patients also received external beam radiation in conjunction with intralesional radiation therapy. Fourteen patients had primary lung cancer. A complete response was obtained in 5 of the 14 patients. Ten of the 14 patients with primary non-small-cell carcinoma of the lung showed a significant response to treatment (greater than 50 percent reduction in tumor measurement). Six patients with metastatic lesions also were treated. Five of the six showed a significant tumor response measured as either 50 percent reduction in tumor measurement or complete pain relief. The only significant complication was pneumothorax (6 of the 20), which did not prevent completion of any treatment plan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.