Abstract

Percutaneous absorption is highly variable between chemicals but also within chemicals depending on exposure conditions and experimental set up. We tested a larger number of organic solvents with the same experimental set up, using skin from new-born piglets and static diffusion cells. Thirty-six common organic solvents were studied neat (and 31 of them also in water dilution): acetone, acetonitrile, n-butanol 2-butanone 2-butoxyethanol, 1-butoxy-2-propanol, n-butyl acetate, butyl acrylate, cyclohexane, cyclohexanone, 1,2-dichloroethane, dichloromethane, ethanol, 2-ethoxyethanol, ethyl acetate, ethyl acrylate, ethylbenzene, furfuryl alcohol, n-hexane, 2-hexanone, 2-isopropoxyethanol, methanol, 1-methoxy-2-propanol, methyl acrylate, 3-methyl-1-butanol, methyl tertiary butyl ether, 4-metyl-2-pentanol, methyl methacrylate, 2-propanol, 2-propen-1-ol, 2-propoxyethanol, 1-propoxy-2-propanol, styrene, trichloromethane, toluene and m-xylene. In addition, a mixture of 2-methylbutyl acetate and n-pentyl acetate was tested. For most of the solvents, little or no percutaneous absorption data have been published. Lag times, steady-state fluxes and apparent permeability coefficients were obtained from the time courses of solvent appearance in the receptor medium, as measured by gas chromatography. The use of the same methodology and kind of skin resulted in small variability within experiments, underlining the need for consistent methodology for useful results for developing predictive models. Furthermore, a comparison of the neat and diluted data shows that water dilution affects all these variables and that the direction and magnitude of the effects vary between chemicals. This comparison strongly supports that prediction of percutaneous absorption of neat and water diluted chemicals requires different models.

Highlights

  • Understanding percutaneous absorption of organic solvents is important in many areas, such as prediction of the time-to-effect of topically administered medications, the retention and behaviours of cosmetics on the skin, or risk assessment of unintended exposures

  • A commercially available mixture of n-pentyl acetate (628-63-7) and 2-methylbutyl acetate (624-41-9) was obtained from Sigma Aldrich (Steinheim, Germany) in a 65%/35% mixture having 99% purity, proportions were 60% and 40% according to our analysis by gas chromatography

  • The present study adds to the body of evidence showing that Kp is concentration dependent, and that the influence of water dilution varies significantly between chemicals

Read more

Summary

Objectives

The purpose of the present study was to evaluate the dermal penetration potential of a number of chemicals relevant for the occupational setting, namely organic solvents

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call