Abstract

Palu City is located in an earthquake-prone area. To Construct a building in earthquake-prone areas, many people like to construct buildings far away from the epicenter, we should be able to construct buildings in earthquake-prone areas without any worries about the resilience of the building related to seismic load. In this final project, a 4 (four) storey shophouse will be designed as the Special Moment Resisting Frame method using the SNI-2847-2019 and SNI- 1726-2019 standard. The seismic load was simulated using the response spectrum and the structural element was analyzed by 3D Structural Analysis Programme. The design results meet the dimensions of each structural elements. There were slab thickness 125 mm, column dimensions 600 mm x 600 mm, dimensions of beam 400 mm x 600 mm, the dimensions of the joist 200 mm x 400 mm and tie beam dimension 400 mm x 600 mm with the reinforcement obtained from each structural element meet the requirements of SNI-2487- 2019, Standard of structural concrete for buildings.