Abstract

Hydraulic ram pump is operated without fuel and only rely on the height difference of the water source. tube compressor serves to continue the flow of water and increase the pressure in the hydraulic ram pump. To improve the performance of the hydraulic ram pump, experiment with variable position of the tube compressor has been done. The tube compressor is placed on the side of the valve after intake and waste, as well as with an outlet at the bottom of the tube compressor. The experiments were performed on the flow of water from a height of 2.1 m, 2.6 m, 3.1 m, 3.6 m and 4.1 m. The test results showed that the position of the tube compressor affect the performance of the hydraulic ram pump. Tube compressor is placed after the input side and the waste valve has a value greater than the tube compressor that is placed between the input and exhaust valves. The volumetric flow rate output, maximum head, suction force, and the largest thrust force obtained at a height of 4.1 m with the results of each 0.121 l / sec; 16 m; 156.499 N; and 89.48 N. While the largest pump efficiency obtained at a height of 3.1 m waterfall which is 2.618%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.